ATM SAFE

ATM Safe Door & Cutting Protection

Keep your ATM SAFE

Organised Criminal Gang Attacks

Most physical ATM crime is carried out by organised criminal gangs. They usually choose the ATM make and model that they have worked out how to open the safe door quickly and steal the cassettes full of cash. Historically they will steal an ATM and then do their research first and perfect the opening method.

One example of this was a gang who hit Wincor 1500 internal ATM’s at motorway services and with a powered grinder cut below the Cencon lock and opened the safe stealing the cash within 3 minutes. They didn’t care that the services was staffed at the time!

How To Protect and Disrupt The Criminal

The fast response to these attacks was for ATM SAFE to quickly produce a batch of Kaba Cencon ACP (anti cut plate) protection and install them at a high rate of knots across the country. A higher level of protection was then scheduled in to install our Live Pluslock re-locking devices to all the ATM so the grinder attack was no longer effective.

The visual ACP bought the ATM companies time and in combination with the Pluslocks the gang stopped attacking the ATM’s saving our clients 100’s of thousands of pounds per week.

ATM Safe Door

ATM Safe Pluslocks

Also known as safe AED’s (anti explosive devices), Re-lockers or ADK (anti drill kits) systems.

Re-locker mechanisms built into high security vault doors and safes have been used for centuries, they are intended to keep the door locked in a burglary attempt.

Most UL ATM’s and lower level Cen L safes rely on the Cencon lock only for locking protection. The safe door can be easily compromised by drilling or cutting because it is generally a mild steel construction and has no or little internal re-locking devices.

We have designed a number of Pluslocks that can be installed to relock the safe door under various attacks. These attacks are usually drilling, grinding or using an oxy torch on the safe door to gain access.

At the heart of our re-locking system is our Live Pluslock which adds an additional live locking position within the safe that is operated when closing the Cencon lock.

We have installed 1000’s of Pluslocks saving the industry millions of pounds over the years.

Enhanced Protection with Live
and Dead relocking Plus Locks

The live lock provides an instant mechanically driven hidden secondary lock position operated by using the Cencon lock in the normal operation.

Great protection against the horizontal grinder, oxy and drill attacks below the ATM Cencon safe lock.

The Dead locks provides an extra locking position fired when under attack providing additional protection to the live lock. Multiple dead lock positions can be installed within the ATM safe door.

The Dead VCD’s fire provides protection from above and below the safe door, offering vertical defense—especially crucial when attempts are made to cut through the bolt strap or breach the ATM safe door.

Cencon ACP

The Cencon ACP (anti cut plate) has been designed as a fast deploy deterrent (no safe access required) and protection against the cutting and drill attacks below the Kaba Cencon lock.

Hand built and filled with our own attack resistant chemical composite mix and Steel Diamond Mesh by our ATM SAFE engineers.

Cencon LACP

The L-ACP (large anti cut plate) can be used to protect more of the safe door and Cencon safe lock for larger ATM’s.

We recommend adding a Pluslock inside the safe door, the ultimate relocking system for ATM’s in critical attack areas.

Image shown with L-ACP (anti cut plate) and DACP (Dispenser anti cut plate)

DACP – Dispenser Anti Cut Plate

The DACP (Dispenser Anti Cut Plate) is a steel fabrication welded and filled with our own attack resistant chemical composite mix, steel filings and re-bar that is bolted from the inside of the ATM to make a secure tamper proof fixing.

The DACP is a useful long life replacement for the standard NCR plastic cover, while also safe guarding against Oxy, drill and grinder attacks to the dispenser area of the safe door.

A common attack on these ATM’s was to pry the outer plastic cover off, remove the cash dispenser door plate and now with the larger opening crow bar and smash down into the cassettes to steal the cash. This is another upgrade that has successfully protected and saved millions of pounds over the years.

The DACP is also a great off the shelf long life replacement for the plastic dispenser cover for the NCR 5877 or P77 ATM POD as it’s widely known.

E-Frame

The ATM E-FRAME upgrade protects against many of the recent physical attacks by adding a 60mm steel and composite armoured barrier in key locations of the safe door.

This helps protect against full door cuts, Oxy attack and grinder attacks below the Cencon safe lock, as well as protecting the safe door and lock, it is also designed to protect re-locker locations.

Hand built and filled with our own attack resistant chemical composite mix and Steel Diamond Mesh by our ATM SAFE engineers.